Sign In | Join Free | My xxjcy.com
China Tianjin Estel Electronic Science and Technology Co.,Ltd logo
Tianjin Estel Electronic Science and Technology Co.,Ltd
TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO.,LTD (ESTEL(GUANGDONG) TECHNOLOGY CO., LTD) We are the professoinal supplier of outdoor telecom cabinet, air conditioner, heat exchanger, and telecom
Verified Supplier

10 Years

Home > Outdoor Cabinet Air Conditioner >

MGA3000/E1 Outdoor Telecom Cabinet with 3000W AC Power Supply, IP55 Rating, 220V

Tianjin Estel Electronic Science and Technology Co.,Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

MGA3000/E1 Outdoor Telecom Cabinet with 3000W AC Power Supply, IP55 Rating, 220V

Brand Name : Estel

Model Number : MGA3000/E1

Certification : CE UL FCC

Place of Origin : China

MOQ : 1 SET

Price : USD200-USD1000

Payment Terms : T/T, Western Union

Supply Ability : 5000

Delivery Time : 10 days

Packaging Details : Wooden case

Noise Level : ≤60dB

Finish : Outdoor type powder coating

Heat Exchanger : 75W/K

Rohs Compliant : Yes

Input Voltage : AC 220V±15% 50Hz

Installation Mode : door mounted/side mounted

Dimensions : 600mm x 500mm x 400mm

Installation Environment : Outdoor telecom enclosure

Power Supply : 220V/50Hz

Power : 1300

Color : Grey

Power Input : 220VAC

Ip Grade : IP55

Material : Galvanized Steel

Compressor Type : Rotary

Contact Now

 
MGA3000/E1 Outdoor Cabinet Air Conditioner Refrigeration Product Self-developed for Cabinet
 
 
1.Introduction
 
1.1. Preface
This manual introduces the guide for the installation, operation, function and routine maintenance of
the cabinet air conditioner. Please read carefully the manual before using and follow the usage and note.
Note: All the operations of this product shall be performed by professional engineers.
1.2. Product introduction
The air conditioner is one kind of refrigeration product self-developed for cabinet. It is applicable in
the place where the cabinet internal heat is very large, the internal electronic equipment is sensitive to the
environment temperature and which should be isolated internally and externally completely. This product
has multiple functions, high reliability, and has the feature that it can start to work without complex
debugging after powering.
The fan in the internal cycle air path absorbs the hot air from the upside to make air heat exchange
by evaporator fins, and sends the cooled air from the downside of the air conditioner. By so, the air in
cabinet can cycle to achieve the purpose of lowering the temperature. Meanwhile, The fan in the external
cycle air path absorbs the external cold air from the downside, and discharges the hot air from the upside
after heat exchange.
 
2. Product parameter
 
2.1. Product technology parameters
Item Name Unit Parameter
Dimension and installation Body outline dimension (widthheightdepth) mm 784*619*245
  Outline dimension including mm /
flange (widthheightdepth) Weight Kg 40
  Installation method   Floor Mounted
  Installation method   Outdoor
Environment and protection Working environment temperature °C -40 to +55
  Noise dB(A) 65
  Life expectancy Years >10
  IP grade   IP55
  Refrigerant   R134a
  ROHS certification   yes
  Input voltage range   220±15%VAC/50Hz
Performance Refrigerating capacity (L35/L35) W 3000
  Rated Refrigerating input power (L35/L35) W 1280
  Rated Refrigerant current (L35/L35) A 5.8
  Maximum Refrigerating current A 8.5
  Heat capacity (optional) W 1000
  Air volume of Inner Circulation M3/h 900

 

2.2. Installation diagram
 
MGA3000/E1 Outdoor Telecom Cabinet with 3000W AC Power Supply, IP55 Rating, 220V
Note: the installation diagram is just for reference, the specific installation scheme should be
determined according to the environment of the actual usage
 
 
3. Preparation and installation
 
3.1. Removing package and checking
1. Please prepare installation tools: knife and scissors, and wear protective gloves.
2. Please remove wrapping film and packing belt, then remove the carton, take out the air
conditioner.
3. Please check the attachment list and accessory bags in the carton, check whether the air
conditioner model is right.
 
Notes:
1. After removing the outer package, please make sure that the air conditioner is placed
upright , and not placed horizontally or upside down.
2. After removing the outer package, please check carefully whether the appearance of the air
conditioner is damaged or oil polluted, if the appearance of the air conditioner has obvious
deformation or oil stain, please contact the manufacturer in time.
3. If there is no need to install the product immediately or it needs to be transported to other
place, please repack the air conditioner after the checking.
4. It is recommended to recycle the unpacking materials.
3.2. Mechanical installation
Installation tool: Phillips screwdriver
Installation Steps:
1) Choose cut location on the cabinet according to the holing diagram, remove the shadow
area and make the installation hole.
2) Make air conditioner flange close to cabinet door, Fix the air conditioner on the installation
surface of the cabinet firmly with M5 screws.
3) Check whether air conditioner is installed levelly and firmly.
Notes:
1) Check whether air conditioner drainage loop is smooth, in case that drainage is blocked.
2) When determine the location of the installation hole in the cabinet, you should avoid the inlet
and outlet air ports inside the cabinet are not blocked by any components inside the cabinet, and
the two should be kept a horizontal distance of more than 150mm; otherwise, it is prone to lead
to r short circuit of the return air, and poor cooling effect, etc.;
3) Carrying or moving the air conditioner should be careful to avoid colliding it and scratching
its surface coating;
 
3.3. Electrical installation
(1) Power input port
Item Port Definition
Live L Power input cable L
Null N Power input cable N
Earth PE Earth line

 

 

(2) Alarm output and signal input port
 
Item Port Definition
+ RS485 communication interface RS485A RS485 communication ports (+)
- RS485 communication interface RS485B RS485 communication ports (-)
The public alarm dry nod (NO) NO It is normally open if no alarm
The public alarm dry nod (COM) COM Common port
The public alarm dry nod (NC) NC It is normally close if no alarm
 
4. Product function
 
4.1. Cooling
When the temperature inside cabinet is higher than refrigeration starting temperature, it starts
refrigerating; when the temperature inside cabinet is lower than refrigeration stopping temperature, it
stops refrigerating.
 
Parameter Default value Setting range Unit Note
Refrigeration starting temperature 32 [20~40] °C Refrigeration stopping temperature = Refrigeration starting temperature - Refrigeration return difference
Refrigeration return difference 5 [3~10] °C  

 

 

4.2. Heating(Optional)
When the temperature inside cabinet is lower than heating starting temperature, it starts heating;
when the temperature inside cabinet is higher than heating stopping temperature, it stops heating.
 
Parameter Default value Setting range Unit Note
Heating starting temperature 5 [-10~15] °C Heating stopping temperature = Heating starting temperature + Heating return difference
Heating return difference 10 [3~15] °C  

 

 
4.3. Remote monitor
Air conditioner has an RS485 communication interface, supporting MODBUS- RTU communication
protocol.The air conditioner communicates with the upper monitor through the RS485 communication
interface. Or users can check the air conditioner’s running state by viewing the display screen directly and
change its running parameters.
 
4.4. The control of external fan (Optional)
According to the optional requirement, the external fan (Hydrogen discharge / emergency fan)19
automatically realizes cycle hydrogen discharging and emergency ventilation function.
Hydrogen discharge function(Optional):When hydrogen discharge cycle comes, air conditioner start
the hydrogen discharge fan, the control switch closes.
 
Parameter Default value Setting range Unit
Cycle 24 [0~72] h
Discharging time 5 [0~10] Min
 
Emergency ventilation function (Optional): When the temperature inside cabinet is higher than
Emergency ventilation starting temperature, emergency ventilation fans run; when the temperature inside
cabinet is lower than Emergency ventilation stopping temperature, emergency ventilation fans stop.
 
Parameter Default value Setting range Unit
Starting temperature 45 [28~50] °C
Stopping temperature 42 [25~50] °C

 

 

5. Display screen
 
5.1. Display interface
 
NO. Icon Function Function explanation
1 ❄️ Refrigerating running Indicate whether refrigerating runs or not
2  

 

 

 


Product Tags:

Outdoor cabinet AC 3000W

      

IP55 telecom enclosure

      

220V outdoor air conditioner

      
Buy cheap MGA3000/E1 Outdoor Telecom Cabinet with 3000W AC Power Supply, IP55 Rating, 220V product

MGA3000/E1 Outdoor Telecom Cabinet with 3000W AC Power Supply, IP55 Rating, 220V Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Tianjin Estel Electronic Science and Technology Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)