Brand Name : Estel
Model Number : MGA3000/E1
Certification : CE UL FCC
Place of Origin : China
MOQ : 1 SET
Price : USD200-USD1000
Payment Terms : T/T, Western Union
Supply Ability : 5000
Delivery Time : 10 days
Packaging Details : Wooden case
Noise Level : ≤60dB
Finish : Outdoor type powder coating
Heat Exchanger : 75W/K
Rohs Compliant : Yes
Input Voltage : AC 220V±15% 50Hz
Installation Mode : door mounted/side mounted
Dimensions : 600mm x 500mm x 400mm
Installation Environment : Outdoor telecom enclosure
Power Supply : 220V/50Hz
Power : 1300
Color : Grey
Power Input : 220VAC
Ip Grade : IP55
Material : Galvanized Steel
Compressor Type : Rotary
Item | Name | Unit | Parameter |
---|---|---|---|
Dimension and installation | Body outline dimension (widthheightdepth) | mm | 784*619*245 |
Outline dimension including | mm | / | |
flange (widthheightdepth) | Weight | Kg | 40 |
Installation method | Floor Mounted | ||
Installation method | Outdoor | ||
Environment and protection | Working environment temperature | °C | -40 to +55 |
Noise | dB(A) | 65 | |
Life expectancy | Years | >10 | |
IP grade | IP55 | ||
Refrigerant | R134a | ||
ROHS certification | yes | ||
Input voltage range | 220±15%VAC/50Hz | ||
Performance | Refrigerating capacity (L35/L35) | W | 3000 |
Rated Refrigerating input power (L35/L35) | W | 1280 | |
Rated Refrigerant current (L35/L35) | A | 5.8 | |
Maximum Refrigerating current | A | 8.5 | |
Heat capacity (optional) | W | 1000 | |
Air volume of Inner Circulation | M3/h | 900 |
Item | Port | Definition |
---|---|---|
Live | L | Power input cable L |
Null | N | Power input cable N |
Earth | PE | Earth line |
Item | Port | Definition |
---|---|---|
+ RS485 communication interface | RS485A | RS485 communication ports (+) |
- RS485 communication interface | RS485B | RS485 communication ports (-) |
The public alarm dry nod (NO) | NO | It is normally open if no alarm |
The public alarm dry nod (COM) | COM | Common port |
The public alarm dry nod (NC) | NC | It is normally close if no alarm |
Parameter | Default value | Setting range | Unit | Note |
---|---|---|---|---|
Refrigeration starting temperature | 32 | [20~40] | °C | Refrigeration stopping temperature = Refrigeration starting temperature - Refrigeration return difference |
Refrigeration return difference | 5 | [3~10] | °C |
Parameter | Default value | Setting range | Unit | Note |
---|---|---|---|---|
Heating starting temperature | 5 | [-10~15] | °C | Heating stopping temperature = Heating starting temperature + Heating return difference |
Heating return difference | 10 | [3~15] | °C |
Parameter | Default value | Setting range | Unit |
---|---|---|---|
Cycle | 24 | [0~72] | h |
Discharging time | 5 | [0~10] | Min |
Parameter | Default value | Setting range | Unit |
---|---|---|---|
Starting temperature | 45 | [28~50] | °C |
Stopping temperature | 42 | [25~50] | °C |
NO. | Icon | Function | Function explanation |
---|---|---|---|
1 | ❄️ | Refrigerating running | Indicate whether refrigerating runs or not |
2 |
![]() |